Combination cases
This case consists of combining the results of load cases, dynamic cases or previously calculated
combination cases to form a new case.
When selecting Combination cases, all existing combinations are listed in the combobox :
The cases appear with their Case number + Title.
1. General
When editing, the definition window shows up :
Enter a Case number and a Title.
Ref. case :
The allowable stress is evaluated at the temperature of the refence case (room temperature if not specified).
Level :
This field is intended for nuclear codes only. The possible values are : A (normal conditions), B (upset), C (emergency), D (faulted) and T (test).
Equation :
- 1- None
- 2- All
Method :
- 0- Algebraic addition
- 1- Absolute addition
- 2- SRSS
- 3- Seismic
- 4- Maximum absolute
- 6- Algebraic maximum
- 7- Algebraic minimum
- 8- Range
- 9- Max resultant moment range
Check fasteners :
If checked, the fasteners will be verified.
Duration :
In hours.
2. Combined cases
Enter the number of the constituent cases and the corresponding factor (1) :
On right side, as a reminder, the list of all cases (2). You can filter them by selecting the type :
- All
- Static
- Dynamic
- Combination
- External cases