Components

In this section, libraries of components can be created.

A library is a JSON file with a name, a reference to a piping library and a list of components.

Components are :

  • Valves
  • Flanges
  • Bellows
  • Sockets

Image

1. Organisation

On the left panel, you can create folders, sub-folders and libraries.

The - button is used both for removing folders and libraries.

A folder can be a type of component or a specific provider.

You can also drag a file/folder on another folder.

2. Library

A library can be managed as you want.

It can correspond to a provider of several component (Ex : flanges, bellows and sockets) or be specific to a product (Ex : only valves).

A library is referenced to an existing Piping library for the size definitions. Units are then imposed.

You can choose the type :

  • All
  • Valves
  • Flanges
  • Bellows
  • Sockets

2.1 Valves

Click the + button to add valves for a specific pipe size. Select a size (Ex : 4”) :

Image

For this size, create several Ratings (max service pressure). It is a text and is just informative (Ex : 50).

Click the + button to add a new valve of a certain type :

  • Simple
  • With middle point
  • With eccentricity
Property Unit Metric Unit USA
Length m ft
Mass ton kips
Thickness factor - -
The wall thickness is increased by the thickness factor by equally increasing the outer diameter and decreasing the inner diameter, keeping the mean diameter the same as that of connected pipe. The thickness value is reduced if the wall thickness is too great. Default = 3.

The connection indicates how the valve is connected to the pipes :

  • None
  • Butt weld - flush
  • Butt weld - as welded
  • Fillet weld
  • Full fillet weld
  • Threaded
  • Brazed

2.2 Flanges

Click the + button to add flanges for a specific pipe size. Select a size (Ex : 4”) :

Image

For this size, create several Ratings (max service pressure). It is a text and is just informative (Ex : 50).

Click the + button to add a new flange of a certain type :

  • Welding neck
  • Slip-on
  • Lap joint
  • Threaded
  • Socket welding
  • Blind
Property Unit Metric Unit USA
Length m ft
Mass ton kips
Thickness factor - -
Diameter of the flange mm in
Thickness of the flange mm in
The wall thickness is increased by the thickness factor by equally increasing the outer diameter and decreasing the inner diameter, keeping the mean diameter the same as that of connected pipe. The thickness value is reduced if the wall thickness is too great. Default = 3.

2.3 Bellows

Click the + button to add bellows for a specific pipe size. Select a size (Ex : 4”) :

Image

For this size, create several Ratings (max service pressure). It is a text and is just informative (Ex : 50).

Click the + button to add a new bellow of a certain type :

  • Axial : Axial and lateral displacements and rotations are permitted
  • Lateral in a single plane : Lateral displacements are only permitted in the plane defined by the local axes Z’ and X’. No axial displacements nor rotations are permitted
  • Lateral in all planes : Lateral displacements are permitted in all directions perpendicular to the element axis Z’. No axial displacements nor rotations are permitted
  • Angular in a single plane : Rotations are only permitted about the local axis Y’. The movements are thus restricted to the plane defined by the local axes Z’ and X’
  • Angular in all planes : Rotations are permitted about all axes perpendicular to Z’
Property Unit Metric Unit USA
Length m ft
Distributed mass ton kips
Pressure area mm² in²
Axial stiffness kN/mm kips/in
Lateral stiffness kN/mm kips/in
Angular stiffness kN.m/rad kips.ft/rad
Torsional stiffness kN.m/rad kips.ft/rad
If Torsional stiffness is zero or blank, the joint is modeled as rigid in torsion and the user should verify that the moments about the element axis Z’ are acceptable.

One half of the mass will be concentrated at each end of the bellow.

2.4 Sockets

Click the + button to add sockets for a specific pipe size. Select a size (Ex : 4”) :

Image

For this size, create several Ratings (max service pressure). It is a text and is just informative (Ex : 50).

Click the + button to add a new socket.

Property Unit Metric Unit USA
Length m ft
Mass ton kips
Thickness factor - -
The wall thickness is increased by the thickness factor by equally increasing the outer diameter and decreasing the inner diameter, keeping the mean diameter the same as that of connected pipe. The thickness value is reduced if the wall thickness is too great. Default = 3.