Primary floor response cases
This load describes the floor response spectra for each support level. This analysis is used to
obtain bound solutions for simple multilevel cases (including single level cases) for which the
dynamic loading is entirely due to movements at the support points.
The "levels" are groups of supports which are moving in parallel and are entered using the level
number field on supports.
Attention, to obtain the complete solution for multilevel problems, it is necessary to calculate the primary and secondary parts of the solution separately and then to combine them.
MetaStructure will calculate the bounds for the PRIMARY part of the solution u(t) for displacements, rotations, forces, moments and stresses due to the dynamic support movement loading.
When selecting Primary floor response cases, all existing primary floor response cases are listed in the combobox :
The cases appear with their Case number + Title.
1. General
When editing, the definition window shows up :
Enter a Case number and a Title.
Event :
Select a Spectra : R.G. 1.60 - 2% Damping in this example.
See §2.
Level :
This field is intended for nuclear piping codes only. The possible values are : A (normal conditions), B (upset), C (emergency), D (faulted) and T (test).
Equation :
The equations are code-dependent.
Method :
For intermodal :
- 1- Grouping
- 2- Ten percent
- 3- Double sum
- 4- SRSS
- 5- All coupling
- 6- Rosenblueth
- 7- Der Kiureghian
For interlevel :
- 0- Absolute without phase
- 1- SRSS without phase
- 2- Algebraic
- 3- Absolute with phase
- 4- SRSS with phase
- 5- Envelope
- 6- SRSS with counterphase
For order :
- 0- Interlevel / Intermodal / Interspatial
- 1- Interlevel / Interspatial / Intermodal
- 2- Intermodal / Interlevel / Interspatial
Rigid correction :
- 0- SRSS
- 1- None
- 2- Absolute
- A- SRSS with modal
- B- Gupta
- C- Lindley-Yow
X, Y, Z multipliers :
This factor multiplies the X, Y, Z component of the loading.
If a factor is zero or blank, then the corresponding loading component will be zero.
Check fasteners :
If checked, the fasteners will be verified.
2. Spectra definition
In this example, we use this Spectra loading :
It contains 2 LEVELS with corresponding spectra :
Click here for more information about the spectra definition.
3. Restraint defintion
In this example, all restraints are assigned a LEVEL :
4. Secondary floor response cases
Click here for more information about the secondary floor response cases.